Compatibility & Specifications by Device

Modified on Mon, May 20 at 11:58 AM

UNIVERSAL COMPATIBILITY
Bluebot auto-adjusts itself to fit eighty (80) pipe size and type combinations through
patented Robot AI servoing guided by the Bluebot mobile App. As more pipe sizes and
types are added in the future, customers get them for free.


Pipe Sizes:
Standard : 3/4”, 1.0”, 1.25”, 1.5”, 2.0”
Large: 2.5”, 3.0”, 4.0” (Special Calibration “Prime Versions”)
Pipe Types: Copper (Type L & M), PVC (Sch. 40 & 80), CPVC (Sch. 40 & 80), PEX,
PE, Galvanized, Stainless Steel


PERFORMANCE SPECS
Accuracy: +/- 1.0% to 2.0% of flow reading (application, pipe size and type dependent)
Repeatability: +/- 0.2%of flow reading
Low
Flow
Capability: From 0.1 to 
0.5 gpm | 0.38 to 1.9 lpm (Pipe size dependent)
High Flow Capability: Maximum 
flow
 for
 pipe 
size


Wi-Fi NETWORKING
Flow Meter Data Communication: 2.4GHz Wi-Fi
Signal: Full bars of signal required during meter Wi-Fi commissioning; Minimum of one
bar of signal at meter install location
Connection Range*: Approximately 30ft (9m), strong Wi-Fi signal required
Number of Devices: Unlimited
Number of Locations: Unlimited
LoRa Signal Outage: Meter automatically reconnects to cloud when Signal is restored.
*See LoRa Bluebot solutions for longer internet connection ranges up to 1000Ft (305M);
1.2MI (1.93KM) line of sight.


OPERATING SPECS
Measured Fluid: Water / Grey Water
Temperature:
 0°
C 
to 
50°
C
 |
 32°
F 
to
 122°
F
Power Supply: Supplied with 10ft (3m) power cable, USA plug /110VAC (No batteries
required)
Power Outage: Meter automatically reconnects to cloud when Power is restored.
Meter Input Power: 5V, 1A


INSTALLATION

App: Download the Bluebot App at the Apple App Store or Google Play, Search
“bluebot water”
App Guided Commissioning: Appx.10min App led; 3-steps
1)
Survey,


2)
Connect 
to 
network,


3) Clamp 
on 
pipe, auto-adjusts and sets
Method:
 Clamp‑on outside of pipe,
no
pipe
cutting
or shutdowns required
Meter Orientation:
Any 
angle,
 horizontal, vertical, bi-directional flow


PHYSICAL SPECS
Meter: Ingress rating indoor/outdoor use NEMA 6 / IP67; Footprint Length 4.13in
(105mm); Weight 0.8lbs (0.36kg)
SOFTWARE COMPATIBILITY
Apple Phone/Tablet iOS 14 or newer
Android Phone/Tablet Android OS 12 or newer
Web Dash - All internet browsers


GENERAL
Technology: Transit-Time Ultrasonic
Patented: US
105510231 Adjustable Angle Technology (AAT)
FCC ID: 2AHMR-ESP07S
CE Approved




LoRaPTP (Point to Point Meter)


UNIVERSAL COMPATIBILITY
Bluebot auto-adjusts itself to fit eighty (80) pipe size and type combinations through
patented Robot AI servoing guided by the Bluebot mobile App. As more pipe sizes and
types are added in the future, customers get them for free.

Pipe Sizes:
Standard : 3/4”, 1.0”, 1.25”, 1.5”, 2.0”
Large: 2.5”, 3.0”, 4.0” (Special Calibration “Prime Versions”)
Pipe Types: Copper (Type L & M), PVC (Sch. 40 & 80), CPVC (Sch. 40 & 80), PEX,
PE, Galvanized, Stainless Steel

PERFORMANCE SPECS
Accuracy: +/- 1.0% to 2.0% of flow reading (application, pipe size and type dependent)
Repeatability: +/- 0.2%of flow reading
Low
Flow
Capability: From 0.1 to
0.5 gpm | 0.38 to 1.9 lpm (Pipe size dependent)
High Flow Capability: Maximum 
flow 
for
 pipe 
size

LoRa NETWORKING
Data Communication: Lora radio communication protocol
Flow Meter: No Wi-Fi needed; Meter auto-connects to a LoRaPTP Bridge via RF
Connection Range: Approximately 1000Ft.(305M); 1.2MI (1.93KM) line of sight
Number of Devices: Paired set - one meter + one LoRaPTP Bridge
Number of Locations: Unlimited, recommend 1-3 meters per location
LoRaPTP Bridge: Connect to the internet via Ethernet cable to router or available Wi-
Fi, flow data streamed to Cloud (For 4G LTE see LoRaWAN Bluebot Solution)
LoRa Signal Outage: Meter automatically reconnects to cloud when Signal is restored.


OPERATING SPECS
Measured Fluid: Water / Grey Water
Temperature:
 0°
C
to
50°
C
|
32°
F
to
122°
F

Power Supply: Supplied with 10ft (3m) power cable, USA plug /110VAC (No batteries
required)
Power Outage: Meter automatically reconnects to cloud when Power is restored.
Meter Input Power: 5V, 1A

INSTALLATION
App: Download the Bluebot App at the Apple App Store or Google Play, Search
“bluebot water”
App Guided Commissioning: Appx.10min App led; 3-steps
1)
Survey,


2)
Connect
 to 
network,


3) Clamp 
on
 pipe, auto-adjusts and sets
Method:
 Clamp‑on outside of pipe,
no 
pipe 
cutting 
or shutdowns required
Meter Orientation:
 Any 
angle,
horizontal, vertical, bi-directional flow


PHYSICAL SPECS
Meter: Ingress rating indoor/outdoor use NEMA 6 / IP67; Footprint Length 4.13in
(105mm); Weight 0.8lbs (0.36kg)
LoRaPTP Bridge: Indoor use only; 3.0in (76mm) L x 3.0in (76mm) W x 1.0in (25mm)
H; Weight 0.25lb (0.11kg)

SOFTWARE COMPATIBILITY
Apple Phone/Tablet iOS 14 or newer
Android Phone/Tablet Android OS 12 or newer
Web Dash - All internet browsers

GENERAL
Technology: Transit-Time Ultrasonic
Patented: US
105510231 Adjustable Angle Technology (AAT)
FCC ID: 2AHMR-ESP07S
CE Approved




LoRaWAN-


UNIVERSAL COMPATIBILITY
Bluebot auto-adjusts itself to fit eighty (80) pipe size and type combinations through
patented Robot AI servoing guided by the Bluebot mobile App. As more pipe sizes and
types are added in the future, customers get them for free.

Pipe Sizes:
Standard : 3/4”, 1.0”, 1.25”, 1.5”, 2.0”
Large: 2.5”, 3.0”, 4.0” (Special Calibration “Prime Versions”)
Pipe Types: Copper (Type L & M), PVC (Sch. 40 & 80), CPVC (Sch. 40 & 80), PEX,
PE, Galvanized, Stainless Steel

PERFORMANCE SPECS
Accuracy: +/- 1.0% to 2.0% of flow reading (application, pipe size and type dependent)
Repeatability: +/- 0.2%of flow reading
Low
Flow
Capability: From 0.1 to
0.5 gpm | 0.38 to 1.9 lpm (Pipe size dependent)
High Flow Capability: Maximum 
flow
 for 
pipe
 size

LoRaWAN NETWORKING
Data Communication: LoraWAN radio communication protocol
Flow Meter: No Wi-Fi needed; Meter auto-connects to a LoRaWAN Gateway via RF
Connection Range: Up 
to
 1.2mi (2km) in urban areas; Up
 to
 10mi (15km)
clear 
line 
of 
sight.
Number of Devices: Connect up to 100 devices per Gateway (Model specific)
Number of Locations: Unlimited
LoRaWAN Gateway: Connect to the internet via Ethernet, Wi-Fi, 3G/4G LTE; Flow
data streamed to Cloud
LoRa Signal Outage: Meter automatically reconnects to cloud when Signal is restored.

OPERATING SPECS
Measured Fluid: Water / Grey Water
Temperature:
 0°
C 
to 
50°
C 
|
 32°
F 
to 
122°
F
Power Supply: Supplied with 10ft (3m) power cable, USA plug /110VAC (No batteries
required)
Power Outage: Meter automatically reconnects to cloud when Power is restored.
Meter Input Power: 5V, 1A

INSTALLATION
App: Download the Bluebot App at the Apple App Store or Google Play, Search
“bluebot water”
App Guided Commissioning: Appx. 10min 

App led; 3-steps
1)
Survey, 
2)
Connect 
to 
network,
 3) Clamp
 on
 pipe, auto-adjusts and sets
Method:
 Clamp‑on outside of pipe,
no
pipe
cutting
or shutdowns required
Meter Orientation:
Any
angle,
 horizontal, vertical, bi-directional flow

PHYSICAL SPECS

Meter: Ingress rating indoor/outdoor use NEMA 6 / IP67; Footprint Length 4.13in
(105mm); Weight 0.8lbs (0.36kg)
LoRaWAN Gateways: Indoor options available; Outdoor versions ingress rating NEMA
6 / IP67; Sizes vary
 

SOFTWARE COMPATIBILITY
Apple Phone/Tablet iOS 14 or newer
Android Phone/Tablet Android OS 12 or newer
Web Dash - All internet browsers

GENERAL
Technology: Transit-Time Ultrasonic
Patented: US
105510231 Adjustable Angle Technology (AAT)
FCC ID: 2AHMR-ESP07S
CE Approved




 

Software Specifications


Hardware must be commissioned to the cloud and set up using the "bluebot water" application for iOS or Android.

Apple devices must be running iOS 14 or newer with Wi-Fi ON during setup for a successful device handoff and connection to our cloud.


 



If you have any questions, please submit a support ticket or call (831)275-2715 and leave a message. A member of our support team will call you back within 24 hours.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article